EX Series - Miura Boiler

Details


  • Production capacity: 35-75 t/h
  • Work pressure: 1.25-5.3 MPA
  • Applicable fuel: Bituminous coal, anthracite, meagre coal, lignite, gangue, waste, sludge
  • Applicable industry: Chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital


Product introduction

  As a new mature high-efficiency and low-pollution clean coal technology, circulating fluidized bed combustion (CFBC) technology has many advantages that other combustion methods do not have. Circulating fluidized bed combustion is low-temperature combustion, so the NOx emission is much lower than that of pulverized coal furnace, only 200ppm. CFBC can desulfurize directly during the combustion process, and the desulfurization efficiency is high. The technology and equipment are simple and economic, and the costs of its initial investment and operation are much lower than those of dry pulverized coal furnace and flue gas desulfurization (PC+FCD). The discharged ash residue has good activity and is easy to be comprehensive utilized without secondary ash residue pollution. The load adjustment range is large, and the low load can be reduced to about 30% of the full load.


Quick inquiry:
I need the quotation of , the fuel is , this capacity is , the pressure is , use for . My Name is , my Email is , my phone number is , Please Send the detail information for me!






High temperature cyclone separator
  • High efficiency, wear resistance, separation efficiency ≥ 98%, effectively improve the combustion efficiency of the boiler thermal efficiency.

Large furnace design
  • Large furnace, low velocity design; the application of wearproof tube technology, reducing erosive abrasion.

  • Extend the residence time of coal particles in the furnace so that the coal can be fully burned.

Bell jar type hood
  • Adopt bell type hood to distribute air averagely and avoid fuel reverse to wind chamber.

Low bed pressure operation
  • By particle optimization, the operating bed pressure can be decreased to 3500Pa, which effectively saves operating costs and greatly reduces the oxynitride generated.

Model Rated Thermal Power t/h Working Pressure MPA Rated Output Water Temperature ℃ Thermal Efficiency %
DHX35-1.25-AⅠ 35 1.25 194 89
DHX50-1.25-AⅠ 50 1.25 194 89
DHX75-1.25-AⅠ 75 1.25 194 89
ZZ-35/3.82-AⅠ 35 3.82 450 89
ZZ-50/3.82-AⅠ 50 3.82 450 89
ZZ-65/3.82-AⅠ 65 3.82 450 91
ZZ-75/3.82-AⅠ 75 3.82 450 91
ZZ-75/5.3-AⅠ 75 5.3 485 91

CONTACT FORM



EX Dual Fuel Low NOx Steam Boilers | Miura AmericaThe Miura EX Series steam boilers, with gas and oil fuel options, are ideal for hospitals and other facilities that are required to have a secondary fuel source.. The EX steam boiler uses our floating header design on an upright drum-shaped pressure vessel. With a single button, the Miura EX-Series boiler a from a cold start to full steam output in less than 5 minutes.MIURA EX SERIES STARTUP MANUAL Pdf Download | ManualsLibSummary of Contents for Miura EX Series Page 1 EX BOILER START UP MANUAL MIURA CANADA Co.,LTD MIURA MANUFACTURING AMERICA Co.,LTD Date of issue : Mar. 20, 2013 Boiler Start up Manual Number : T539-998-9022

Industrial & Commercial Steam Boilers | Miura AmericaMiura’s EX industrial boilers are incredibly versatile high-pressure steam systems that may be used with natural gas, propane, or 2 fuel oil. The EX offers NOx ratings as low as 30 ppm depending on the model and a compact footprint that occupies 33% less boiler room space than a typical fire tube boiler.EX Series - MIURA BOILEREX Gas/Oil Series - High Pressure Steam Boiler. Miura’s exclusive “low water content, watertube” design is the most versatile boiler available in the marketplace today. A once-through, forced circulation steam boiler producing steam in just 5 minutes while maintaining an 85% fuel-to-steam efficiency.MIURA EX-300 INSTALLATION MANUAL Pdf Download | ManualsLibView and Download Miura EX-300 installation manual online. EX Series High Efficiency. EX-300 boiler pdf manual download. Also for: Ex-100go, Ex-100g, Ex-200go, Ex-200g, Ex-250go, Ex-250g, Ex-300go, Ex-300g, Ex-100sgo, Ex-100sg, Ex-200sgo, Ex-200sg, Ex-250sgo, Ex-250sg, Ex-300sgo,

EX Series - Product - PT. MIURA INDONESIAThe EX models are fully equipped with all of the functions demanded by a Boiler The EX Series of gas fired steam boilers is the culmination of considerable research using the expertise and maintenance data that Miura has accumulated over many years. Establishes new standars of style, safety and durability.Miura Boilers - Combustion and Control Solutions, Inc.EX Series Models. Our EX Gas/Oil Series High Pressure Steam Boiler is the most versatile industrial steam boiler in the world. The EX design minimizes carryover and produces dry 99+% saturated steam in less than 5 minutes from a cold start. Faster start-up means less fuel used, greater savings, responsible use of precious natural resources.

EX Series Models | Burner CombustionMiura’s EX Series boilers occupy 33% less floor space than typical firetubes, and do not require tube pull space. Compact design means much smaller radiation losses and larger fuel savings. Full Steam Output In Less Than 5 Minutes. Floating headers mean fast start-up. MIURA boilers produce fast steam in less than 5 minutes from a cold start-up.EX Series - Produk - PT. MIURA INDONESIAModel EX sepenuhnya dilengkapi dengan semua fungsi yang diminta oleh Boiler Seri EX dari steam boiler bahan bakar gas adalah puncak dari penelitian yang cukup besar dengan menggunakan data keahlian dan perawatan yang telah diakumulasikan Miura selama bertahun-tahun. Menetapkan standar baru dalam gaya, keamanan dan daya tahan.